Anhui Zhongke Duling Commercial Appliance Co., Ltd.

FOR A HEALTHY WORLD FOR A HEALTHY FUTURE

Manufacturer from China
Verified Supplier
5 Years
Home / Products / Ultra Low Temperature Freezer /

-86 Degrees Auto-Cascade Ultra Low Lab Freezer medical equipment for hospital and college ,labtoratory

Contact Now
Anhui Zhongke Duling Commercial Appliance Co., Ltd.
Visit Website
City:hefei
Province/State:anhui
Country/Region:china
Contact Person:MrMeng
Contact Now

-86 Degrees Auto-Cascade Ultra Low Lab Freezer medical equipment for hospital and college ,labtoratory

Ask Latest Price
Video Channel
Brand Name :METHER
Model Number :MDF-86V838E
Certification :CE
Place of Origin :China
MOQ :1
Price :6394.5-7003.5 per set
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :3000 stes/month
Delivery Time :35 days
Packaging Details :Plywood exporting package
Transport Package :Plywood
Inside material :Stainless steel
Outside material :Color sprayed steel
Capacity :838L
Exterior size(mm) :1160*1172*1994.5
Interior size(mm) :894*718*1310
NT(KG) :391kg
Power(w) :1700W
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

-86 Degrees Auto-Cascade Ultra Low Lab Freezer 838 Liter medical equipment for hospital and college ,labtoratory

Product Description


-86ºC ULT freezer is specially designed and manufactured for long term storage of various biological products, including viruses, germs, erythrocytes, leucocyte and cutis. Applications can be found in blood banks, hospitals, edipemic prevention service, and research institutes, laboratories in electronic and chemical plants, biological engineering institutes and marine fishery companies.

-86°Auto-Cascade ultra low temperature freezer

Auto-Cascade cooling system, cooling fast and easy to maintain, energy saving and environmental protection.

Self-developed mixed refrigerant, 50% energy saving,
Cooling speed increased by 40%.
FILED PROVEN RELIABILITY
  • Unique insulated inner door design for four separate storage compartments to minimize frost buildup inside the chamber.
  • Specialized control system design for a well-balanced operation of dual refrigeration system.
  • Positive filed proven reliability record.


SAFETY
  • Malfunction alarms including high and low temperature, power failure, sensor error, clean-filter, and extremely high ambient, abnormal voltage, thermostat failure, low battery, condenser clean, door ajar.
  • Door open feature standard and USB port for temperature date downloading standard on upright models.
  • Remote alarm contacts.
-86 Degrees  Auto-Cascade  Ultra Low Lab Freezer medical  equipment for hospital and college ,labtoratory
-86 Degrees  Auto-Cascade  Ultra Low Lab Freezer medical  equipment for hospital and college ,labtoratory
ENERGY SAVING
  • Unique door seal design for the minimum loss of cold temperature during a door opening.
  • High performance VIP insulation panels to minimize cabinet heat gain and to improve temperature stability.
  • HC refrigerant with better efficiency and less energy cost.

KEY DESIGN FEATURES
  • Microprocessor-controlled system designed for range of -40°C to -86°C for cabinet space with 1°C increment.
  • Depending on the load demands and ambient conditions, one or both refrigeration systems will operate on demand, ensuring the samples are fully protected under the worst possible condition.
  • Optional temperature recorder, storage racks and box.
-86 Degrees  Auto-Cascade  Ultra Low Lab Freezer medical  equipment for hospital and college ,labtoratory
-86 Degrees  Auto-Cascade  Ultra Low Lab Freezer medical  equipment for hospital and college ,labtoratory

INSTALLATION AND APPLICATION
  • Wide rage operating voltage system from 187V to 242V designed to allow units installed in areas with poor voltage condition
  • Suitable for 10°C to 32°Cambient temperature.


CO2 & LN2 BACKUP SYSTEM
  • Independent equipment CO2 back up system, LN2 back up system a backup refrigeration system for Ultra-Low Temperature Freezer failures and power outages.
  • The backup refrigeration system consists of a control system and a supply connection System.
  • Adjust the solenoid Valve's On-off according to its own temperature control probe.A liquid nitrogen tank or liquid carbon dioxide tank that is connected by a solenoid valve as a Reserve.
  • The solenoid valve is powered by an internal rechargeable battery.
-86 Degrees  Auto-Cascade  Ultra Low Lab Freezer medical  equipment for hospital and college ,labtoratory

Model MDF-86V838E
Specificaitons Shelf/drawer QTY Stainless steel shelf/3
Cooling Direct cooling
Defrost Manual
Refrigerant Mixed-gas
Power Consumption(kWh/24h) 18.8
Noise(db) 55
Ambient temperature(ºC) 10~32ºC
Temperature range(ºC) -40~-86ºC
Cooling system Compressor brand/QTY SECOP/2
Sensor PTC
Temperature controller Microprocessor
Display Digital display
Power Voltage/frequency(V/Hz) 220/50Hz
Power(W) 1700W
Current(A) 9.8A
Material Inside material Stainless steel
Outside material Color sprayed steel
Insulation PURF
Size Capacity(L/cu.ft) 838/29.59
NT./GT.(kg) 344/430
Exterior size(W*D*H)(mm) 1175*1075*1990
Interior size(W*D*H)(mm) 894*718*1310
Package size(W*D*H)(mm) 1270*1100*2185
CBM 3.05
20GP/40GP/40HQ 8/18/18
Frozen Racks Racks 24(5X5)
Boxes (2 Inches) 600
Samples(2ml) 60000
Alarm High/low temperature Y
Power failure Y
Abnormal voltage Y
Sensor error Y
Filter screen check Y
Thermostat failure Y
Low battery Y
Condenser clean Y
High ambient temperature Y
Door ajar Y
Power failure backup system(alarm) 72h
Accessories Castor Y
Inside door 2
Test hole QTY/diameter 1/25MM
USB port Y
Chart recorder /
Data logger Optional
Remote alarm port Y
Optional CO2 back up system Optional
LN2 back up system Optional
Other Certification ISO.CE

Packaging & Shipping

Packing Exporting Plywood package
20GP/40GP/40HQ 12/24/24 Sets
Loading Port: Shanghai/ Ningbo/Hefei
Shipment Term EXW/FOB/CFR/CIF
Payment Term 100% TT Before Delivery

-86 Degrees  Auto-Cascade  Ultra Low Lab Freezer medical  equipment for hospital and college ,labtoratory

Inquiry Cart 0